ISS/Chicago Home


>> Service Request     >> Sales Request       
About UsIntercom EntryCard & TV AccessHealth Care

  > Home: > Products: > Select Engineered Systems



Intercom Entry
> Jeron
> Viscount
> Select Engineered
   Systems

> Aiphone
> Bommer


Please contact our office for additional products, cutsheets, and manuals.

Basic Telephone Entry TEC101

STANDARD FEATURES:

TWO RELAYS NO SUNSHIELD NEEDED TO READ LCD DISPLAY

LCD DISPLAY BACKLIT FOR NIGHT VIEWING

BOARD LEVEL SURGE PROTECTION FOR ALL WIRING, IN AND OUT

TRANSFORMER INCLUDED

PROGRAMMABLE VIA KEYPAD

DISPLAY WORKS IN COLD
OR HOT WEATHER: –0F to +158F

WEATHER RESISTANT HOUSING

TWO YEAR LIMITED WARRANTY *

OPTIONS:

300 - 1200 BAUD MODEM WITH COMPLEMENTARY SOFTWARE

MUI: MULTI UNIT INTERFACE

NO PHONE BILL SYSTEM: ALLIANCE 2002

PEDESTALS AND MOUNTING PLATE


The TEC101 provides basic telephone entry with the SES advantage. TEC101 is offered in two capacities; 50 and 125 to match your building’s requirements. Both units are offered with 2 relays standard and have a two line LCD directory display that is easily read in direct sunlight or at night. As with all SES telephone access systems, the TEC101 is provided with board level surge suppression at no additional cost, and the stainless steel front door and aluminum back box is sure to provide years of faithful service. The TEC101 has a two year limited warranty, and is designed to the same standards as the TEC and CAT product lines.

The best of basic telephone entry, with SES quality.

 

TEC101 FEATURES SPECIFICATIONS Standard Telephone Entry System

FEATURES

  • TEC101 is offered in two capacities 50 and 125. Each offers the same number of phone numbers, PIN codes and names
  • 1 to 6 digit directory code length,programmable.
  • Surge protection is integrated on all inputs and outputs, to minimize adverse effects of transient voltages.
  • Personal Identification Number (PIN code) for resident entry is from 1 to 6 digits, programmable.
  • Voice mail response capability via active keypad, programmable.
  • Hide a name feature, programmable.
  • Two door control relays.
  • Dials out touch tone or rotary.
  • Will not accept touch tone through the microphone.
  • Mutes tones in speaker while dialing.
  • Fully programmable through the keypad.
  • Dials up to 14 digit telephone numbers.
  • Two line LCD display, provides directory names one at a time.
  • Talk time programmable from 1 - 99 minutes.
  • Postal lock capability included.
  • Request to exit inputs for both entrance control relays.
  • Entry code attempts (strike out) is programmable from 0 to 9.
  • Non-volatile memory.
  • Surface or pedestal mounting.
  • Remote door release through telephone touch tone.
  • Programmable background “beep” to indicate the incoming call was placed from TEC101.
  • Manager Password.
  • Battery charging circuit.
  • 2 year limited warranty.

SPECIFICATIONS

  • Outside dimensions: 8 1/2”W x 113/4”H x 3 1/2”D
  • Shipping weight: Approx. 11 lbs.
  • Power: 16.5VAC 20VA transformer (supplied).
  • Construction: stainless steel front door, with aluminum back box.
  • Operating environment: Temperature: - 0F to 158F Relative humidity: 5% to 95% non-condensing
  • Memory type: non-volatile
  • Relay output: Form A or B dry contact 24 V @ 3 AMPS.
  • Tone detection: crystal controlled, will detect short burst 50 millisecond tone.

OPTIONS

  • 300 - 1200 baud modem and complementary software.
  • MUI, Multi Unit Interface: (allows up to 4 TEC101’s on single phone line).
  • Pin hole camera: black and white or color.
  • Semi-flush mount.
  • Handset.
  • Standby battery.
  • No phone bill system:Alliance 2002

APPLICATIONS

  • Apartment buildings.
  • Small gated communities.
  • Condos.
  • Office buildings.

Controlled Access Technology

CAT II


CAT 2 HF

CAT IV


CAT 4 HF

CAT2 and CAT4 Display Features:

  • The CAT 2 provides a single name, backlit LCD display that will scroll both forward and backward. The CAT2 characters that are 5/16” (8 mm) high. This display is very clear, even in bright sunlight. Ideal for small apartments or small gated home sites.


  • The CAT 4 provides a four names at a time with a backlit LCD display that will scroll both forward and backward. The CAT4 characters that are 3/8” (10 mm) high. This display is very clear, even in bright sunlight. Ideal for medium sized apartments, condos or gated communities.

CAT2 and CAT4 Common Features:

  • 14,400 baud modem.
  • 13,000 event log buffer.
  • The CAT 2 and CAT 4 will control two entrances, without options. (two relays)
  • 2 reader inputs (ready to add readers and cards or transmitters and receivers)
  • RS485 expansion port (add up to 12 additional readers and 256 relays)
  • 16 time zones, 16 access levels and 16 access groups.
  • Maximum phone number capacity is 2,700.
  • Maximum card (transmitter) capacity is 16,200 (each with a name attached).

STANDARD FEATURES

  • CAT 2 display provides 2 lines and 1 name per directory screen.
  • CAT 4 display provides 4 lines and 4 names per directory screen.
  • Displays are backlit and visible in bright sunlight .
  • Two wiegand card reader inputs.
  • Two entrance control with 2 relays.
  • RS485 expansion port.
  • Data base has 6 cards per PIN Code / Phone number.
  • 14,400 baud modem.
  • 13,000 event log buffer.
  • Clock calendar.
  • Non-volatile memory.
  • Card/Code expansion remotely.
  • Dials Touch ToneTM or pulse.
  • Programmable via modem.
  • Remotely activated speaker and microphone.
  • Programmable PIN lengths, 1 to 6.
  • REX (request to exit), alarm shunt and door sense input. Multi-level surge suppression protects all electrical connections. Must be grounded.

OPTIONS

  • CATCOM-RF wireless data connection for expansion.
  • NIC, network interface card provides a TCP/IP interface for network programming.
  • OPTK4DR is a plug-on module for expanding the CAT II and CAT IV from 2 readers to 4 readers, internally.
  • CATDR4 is a remote 4 door module that attaches to a CAT system to expand it’s capability up to 14 or 16 entrances depending on CAT configuration.
  • CATRLY8 is a elevator / aux. relay module that contains 8 relays and can be programmed for elevator control, light or HVAC control. Up to 32 CATRLY8 can be connected to a CAT system.
  • RS232 or current loop serial communications.
  • Flush mount ring.
  • Special finishes available upon request.

SPECIFICATIONS CAT 2 shown in the optional lighted weather hood.

The CAT 4 is also offered in the same enclosure, order option OPTKLH.

CAPACITIES

  • Up to 2,700 phone numbers.
  • Up to 2,700 PIN codes.
  • Up to 16,200 cards each with a reference name.
  • Up to 16 entrances, (2 entrances standard)
  • Controls as many as 256 relays for elevator and auxiliary control when adding the CATRLY8. (relay expansion modules)
  • 8 CAT units can be connected to one phone line using MUI’s (one each) and all can be programmed remotely.
  • 13,000 Event Log Buffer (before wrapping)
  • 14,400 Baud modem.
  • Programming for Windows 95, 98 or NT (single user) when used with Selcom2000.
  • Code/Phone/Card capacities can be upgraded by the factory, through authorized dealers only.

SPECIFICATIONS

  • Dimensions: 9 1/2'” W x 13 1/2” H x 3 1/8” D semi flush mount:: 14 5/8” W x 18 5/8” H
  • Material Used: Housing- 12 ga. structural aluminum; Door- 16 ga.stainless steel
  • Finish: aluminum back box: Painted weather resistant finish,
  • Power Input: 18 VAC, 40 VA UL listed transformer (provided with unit).
  • Modem: 14,400 Baud
  • Emergency Battery: 12V .7 AHR GEL CELL on constant charge (for control of line voltage variation and short term telephone support only, optional).
  • Telephone Line: Standard voice grade RJ11C Jack.
  • Mounting: Surface, flush or pedestal mount.
  • Memory Type: Non-volatile.
  • Tone Detection: Crystal controlled, capable of detecting short burst 50MS DTMF tone.
  • Shipping Weight: Approx. 15 lbs.
    GENERAL
  • Operating Environment: Temp.: -20º to 40º C; (CATV temp.: 0º to 40º C) Relative humidity: 5% to 95% non-condensing.
  • Relay Output: Form C dry contact 24V @ 3AMP.
  • FCC Reg.: #CPW74F63331MTE. · ARL LISTED (UL Equivalent)

APPLICATIONS

  • Residential gated communities or commercial use.
  • Apartment buildings / Condominiums / Townhouses.
  • Retirement homes / Convalescent homes.
  • Office buildings.

Telephone Entry Control

TEC II


TEC 2 HF

TEC IV


TEC 4 HF

TEC2 and TEC4 Display Features:

  • The TEC 2 provides a single name, backlit LCD display that will scroll both forward and backward. The TEC2 characters are 5/16” (8 mm) high. This display is very clear, even in bright sunlight. Ideal for small apartments or small gated home sites.


  • The TEC 4 provides a four names at a time with a backlit LCD display that will scroll both forward and backward. The TEC4 characters are 3/8” (10 mm) high. This display is very clear, even in bright sunlight. Ideal for medium sized apartments, condos or gated communities.

TEC2 and TEC4 Common Features:

  • The TEC 2 and TEC 4 will control two entrances, with two relays.
  • Maximum phone number capacity is up to 2,000.
  • Maximum “PIN” number capacity is up to 2,000.
  • Multi-level power surge suppression.
  • Non-volatile memory.
  • High quality stainless steel face for years of service.
  • All pc boards are treated with a moisture barrier.
  • Limited 2 year warranty.

STANDARD FEATURES

  • TEC 2 display provides 2 lines and 1 name per directory screen.
  • TEC 4 display provides 4 lines and 4 names per directory screen.
  • Displays are backlit and visible in bright sunlight .
  • Two entrance control with 2 relays.
  • Non-volatile memory.
  • Dials Touch ToneTM or pulse.
  • Talk time programmable, 1 to 99 minutes.
  • Remote relay activation and latching.
  • Programmable door open and alarm time.
  • Remotely activated speaker and microphone via touch tone after passcode.
  • Programmable “strike out” for PIN attempts.
  • Programmable via keypad.
  • Mutes tones while dialing.
  • Postal lock capability.
  • Programmable open keypad for voice mail.
  • Remotely activated speaker and microphone.
  • Programmable code and PIN lengths, 1 to 6.
  • REX (request to exit), alarm shunt and door sense input.

Multi-level surge suppression protects all electrical connections. Must be grounded.

OPTIONS

  • 1,200 baud modem with TEC Basic software package.
  • NIC, network interface card provides a TCP/IP interface for network programming.
  • OPTKC125 to OPTKC2000 card reader capability, includes two reader input board.
  • OPTK4DR is a plug-on board for expanding the TEC II and TEC IV from 2 reader inputs to 4 reader inputs.
  • RS232 or current loop serial communications.
  • Semi-Flush mount ring.
  • Door sense input & alarm shunt output relay.
  • CCD black & white or color cameras.
  • Clock calendar.
  • Selcom 2002 software for access control programming.
  • Special finishes available upon request.
  • Pedestals and pedestal adapters.

TEC 2 shown in optional lighted weather hood.

The TEC 4 is also offered in the same enclosure. Order option OPTKLH.

CAPACITIES

  • Up to 2,000 phone numbers.
  • Up to 2,000 PIN codes.
  • Up to 2,000 cards (option).
  • Up to 4 entrances, (2 entrances standard)
  • 4 TEC2’s or TEC4’s may share one phone line using MUI’s (one each) and all can be programmed remotely.
  • Programming for Windows 95, 98, ME, 2000 or XP using either TEC Basic or Selcom 2002 (option). Compatibility for NT (single user) is provided with Selcom 2000.
  • Code / Phone / Card capacities can be upgraded by the factory, through authorized dealers only.

SPECIFICATIONS


    TEC2 and TEC4:
  • Dimensions: 9 1/2'” W x 13 1/2” H x 3 1/8” D semi flush mount:: 14 5/8” W x 18 5/8” H
  • Material Used: Housing- 12 ga. structural aluminum; Door- 16 ga.stainless steel
  • Finish: aluminum back box: Painted weather resistant finish.
  • Power Input: 18 VAC, 40 VA UL listed transformer (provided with unit).
  • Modem: 1,200 Baud (option)
  • Emergency Battery: 12V .7 AHR GEL CELL on constant charge (for control of line voltage variation and short term telephone support only, optional).
  • Telephone Line: Standard voice grade RJ11C Jack.
  • Mounting: Surface, flush or pedestal mount.
  • Memory Type: Non-volatile.
  • Tone Detection: Crystal controlled, capable of detecting short burst 50MS DTMF tone.
  • Shipping Weight: Approx. 15 lbs.

GENERAL:

  • Operating Environment: Temp.: -20º to 40º C, Relative humidity: 5% to 95% non-condensing.
  • Relay Output: Form A/B dry contact 24V @ 3AMP.
  • FCC Reg.: #CPW74F63331MTE. · ARL LISTED (UL Equivalent)

APPLICATIONS

  • Residential gated communities.
  • Commercial Buildings.
  • Apartment buildings / Condominiums / Townhouses.
  • Retirement homes / Convalescent homes.
  • Hospitals.
  • Office buildings.

  •  
    ISS/Chicago Home
    About Us | Intercom Entry | Card & TV Access | Health Care
    Service Request | Sales Request | Site Map | Contact Us

    Our new address is:
    4039-43 N. Ravenswood, Chicago, IL 60613
    888-528-4070